ISO-5167
ISO-5167/IAPWS-IF97
ISO-5167: Flow-rate calculation
using PHP and 'Felib.iso5167' COM object
WORKING CONDITIONS:
Type of fluid
Gas
Liquid
Primary device
Orifice with flange tappings
Orifice with corner tappings
Orifice with D and D/2 tappings
Venturi tube with a machined inlet
Venturi tube with an 'as cast' inlet
Venturi tube with a rough-welded inlet
Long radius nozzle
ISA 1932 nozzle
Venturi nozzle (ISA inlet)
Pressure tap location
Upstream measurement
Downstream measurement
Device diameter
d[mm]
Pipe diameter
D[mm]
Differential pressure
Δp[Pa]
Pressure (absolute)
p[Pa]
Density (upstream)
ρ1[kg/m³]
Viscosity (upstream)
μ1[Pa·s]
Isentropic exponent
(ignore for liquids)
κ
RESULTS:
No errors!
Mass rate of flow qm[kg/h]
4093.750783
Diameter ratio β=d/D
0.480000
Coefficient of discharge C
0.603156
Reynolds number ReD
517095.771603
Coeficient of expansion ε
0.942859